Atmos. Chem. Phys. Discuss., 9, 17705-17751, 2009
www.atmos-chem-phys-discuss.net/9/17705/2009/
doi:10.5194/acpd-9-17705-2009
© Author(s) 2009. This work is distributed
under the Creative Commons Attribution 3.0 License.
Review Status
This discussion paper has been under review for the journal Atmospheric Chemistry and Physics (ACP). Please refer to the corresponding final paper in ACP.
Fluorescent biological aerosol particle concentrations and size distributions measured with an ultraviolet aerodynamic particle sizer (UV-APS) in Central Europe
J. A. Huffman1, B. Treutlein1,*, and U. Pöschl1
1Max Planck Institute for Chemistry, Biogeochemistry Department, Becherweg 27, 55128 Mainz, Germany
*now at: Ludwig Maximilians University, Institute for Physical Chemistry, Munich, Germany

Abstract. Primary biological aerosol particles (PBAPs), including bacteria, spores and pollen, are essential for the spread of organisms and disease in the biosphere, and numerous studies have suggested that they may be important for atmospheric processes, including the formation of clouds and precipitation. The atmospheric abundance and size distribution of PBAPs, however, are largely unknown. At a semi-urban site in Mainz, Germany, we used an ultraviolet aerodynamic particle sizer (UV-APS) to measure fluorescent biological aerosol particles (FBAPs), which can be regarded as viable bioaerosol particles representing a lower limit for the actual abundance of PBAPs. Fluorescence of non-biological aerosol components are likely to influence the measurement results obtained for fine particles (<1 μm), but not for coarse particles (1–20 μm).

Averaged over the four-month measurement period (August–December 2006), the mean number concentration of coarse FBAPs was ~3×10−2 cm−3, corresponding to ~4% of total coarse particle number. The mean mass concentration of FBAPs was ~1 μg m−3, corresponding to ~20% of total coarse particle mass. The FBAP number size distributions exhibited alternating patterns with peaks at various diameters. A pronounced peak at ~3 μm was essentially always observed and can be described by the following campaign-average lognormal fit parameters: geometric mean diameter 3.2 μm, geometric standard deviation 1.3, number concentration 1.6×10−2 cm−3. This peak is likely due to fungal spores or agglomerated bacteria, and it exhibited a pronounced diel cycle with maximum intensity during early/mid-morning. FBAP peaks around ~1.5 μm, ~5 μm, and ~13 μm were also observed, but less pronounced and less frequent. These may be explained by single bacterial cells, larger fungal spores, and pollen grains, respectively.

The observed number concentrations and characteristic sizes of FBAPs are consistent with microscopic, biological and chemical analyses of PBAPs in aerosol filter samples. To our knowledge, however, this study reporting: continuous online measurements of bioaerosol particles over several months, a range of characteristic size distribution patterns, and a persistent bioaerosol peak at ~3 μm. The measurement results confirm that PBAPs account for a substantial proportion of coarse aerosol particle number and mass in continental boundary layer air. Moreover, they suggest that the number concentration of viable bioparticles is dominated by fungal spores or agglomerated bacteria with aerodynamic diameters around 3 μm rather than single bacterial cells with diameters around 1 μm.


Citation: Huffman, J. A., Treutlein, B., and Pöschl, U.: Fluorescent biological aerosol particle concentrations and size distributions measured with an ultraviolet aerodynamic particle sizer (UV-APS) in Central Europe, Atmos. Chem. Phys. Discuss., 9, 17705-17751, doi:10.5194/acpd-9-17705-2009, 2009.
 
Search ACPD
Discussion Paper
XML
Citation
Final Revised Paper
Share