Atmos. Chem. Phys. Discuss., 6, 10247-10274, 2006
www.atmos-chem-phys-discuss.net/6/10247/2006/
doi:10.5194/acpd-6-10247-2006
© Author(s) 2006. This work is licensed under the
Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.
Review Status
This discussion paper has been under review for the journal Atmospheric Chemistry and Physics (ACP). Please refer to the corresponding final paper in ACP.
Performance of Chemical Ionization Reaction Time-of-Flight Mass Spectrometry (CIR-TOF-MS) for the measurement of atmospherically significant oxygenated volatile organic compounds
K. P. Wyche1, R. S. Blake1, A. M. Ellis1, P. S. Monks1, T. Brauers2, R. Koppmann1,*, and E. Apel3
1Department of Chemistry, University of Leicester, Leicester, UK
2Institut für Chemie und Dynamik der Geosphäre II, Forschungszentrum Jülich, Jülich, Germany
3National Centre for Atmospheric Research, Boulder, CO, USA
*now at: Bergische Universität Wuppertal, Fachbereich C, Atmosphärenphysik, Wuppertal, Germany

Abstract. The performance of a new chemical ionization reaction time-of-flight mass spectrometer (CIR-TOF-MS) utilising the environment chamber SAPHIR (Simulation of Atmospheric Photochemistry In a large Reaction Chamber – Forschungzentrum Jülich, Germany) is described. The work took place as part of the ACCENT (Atmospheric Composition and Change the European NeTwork for excellence) supported oxygenated volatile organic compound (OVOC) measurement intercomparison during January 2005. The experiment entailed the measurement of 14 different atmospherically significant OVOCs at various mixing ratios in the approximate range 10.0–0.6 ppbV. The CIR-TOF-MS operated throughout the exercise with the hydronium ion (H3O+) as the primary chemical ionization (CI) reagent in order to facilitate proton transfer to the analyte OVOCs. The results show the CIR time-of-flight mass spectrometer is capable of detecting a wide range of atmospheric OVOCs down to sub-ppbV mixing ratios with high accuracy and precision. It is demonstrated that the technique has rapid multi-channel response at the required sensitivity, accuracy and precision for atmospheric OVOC measurements.

Citation: Wyche, K. P., Blake, R. S., Ellis, A. M., Monks, P. S., Brauers, T., Koppmann, R., and Apel, E.: Performance of Chemical Ionization Reaction Time-of-Flight Mass Spectrometry (CIR-TOF-MS) for the measurement of atmospherically significant oxygenated volatile organic compounds, Atmos. Chem. Phys. Discuss., 6, 10247-10274, doi:10.5194/acpd-6-10247-2006, 2006.
 
Search ACPD
Discussion Paper
    XML
    Citation
    Final Revised Paper
    Share